Quantitative fit testing (QNFT) is the most accurate fit testing method - using data to calculate the fit factor. Passing a real-time quantitative respirator fit test proves that the facepiece is sized and donned correctly. Selecting properly fitting respirators and checking daily donning protects workers against insufficient oxygen environments, harmful dusts, fogs, smokes, mists, gases, vapors, and sprays. These hazards may cause cancer, lung impairment, diseases, or death.
Powered by Sibata
VeriFit® Quantitative is manufactured by Sibata Scientific Technology LLC and is exclusively sold by Nextteq® International (NXI®). Sibata, founded in 1921, has become a world leader in environmental testing and developed its first Fit Testing device in 1980. Approx. 50 years of technology and quality is behind the new VeriFit® Quantitative.
Better Value
At Nextteq®, we believe that the products we provide, especially ones that focus on worker safety, should be reliable, high quality, and affordable. The VeriFit® Quantitative does just that!
VeriFit® Quantitative for QNFT
Respiratory fit testing is extremely important in a variety of industries and applications.
Respirators properly worn can protect workers against hazards that may cause cancer, lung impairment, diseases, or death.
The VeriFit® Quantitative can help confirm that there is a tight seal and thereby ensure that workers are receiving the expected level of protection and safety. The instrument measures the fit of the respirator or mask while the user simultaneously performs a series of moving, breathing, and talking exercises designed to simulate the same movements made in the field. With step-by-step guidance, the instrument walks you through the fit test procedure. Once the fit test is complete, it is easy to generate the individual's report.
Easy daily performance using guided prompts
Measurement Modes
1. Perform a Daily Check on the VeriFit® Quantitative.
2. Set up the VeriFit® Quantitative with employee information, type of test, and type of respirator.
3. Perform Training (if required) then perform Fit Test
4. Obtain Results and Generate Reports
NIOSH and OSHA
Their historic roles played in Respiratory Protection for Workers spanning 50 years!
NIOSH (National Institute for Occupational Safety and Health) was established in 1970 as part of the Occupational Safety and Health Act. Its primary role is to conduct research and provide recommendations to prevent work-related injury and illness. NIOSH plays a crucial role in ensuring the safety and effectiveness of respirators used by workers. Their primary functions include:
In essence, NIOSH acts as a watchdog, ensuring that respirators are safe, effective, and meet the needs of workers exposed to various airborne hazards. By certifying respirators, conducting research, providing guidance, and monitoring performance, NIOSH helps to protect the health and safety of workers across a wide range of industries.
The Occupational Safety and Health Act of 1970 established both NIOSH and OSHA within the Department of Labor. NIOSH is responsible for the testing and approval of all respirators used in occupational settings. OSHA’s mission is to ensure safe and healthful working conditions by setting and enforcing standards and by providing training, outreach, education, and assistance.
Under its authority in the OSH Act, OSHA promulgated the Respiratory Protection Standard 29 CFR 1910.134, which requires workplaces using respirators to establish a respiratory protection program and use only NIOSH-approved respirators. This standard also establishes requirements for proper selection, use, and maintenance to ensure the effectiveness of the respirator, as well as medical evaluations, fit testing, and training to maximize protection for the user.
In 2019, OSHA announced changes to their Respiratory Protection Standard. The changes affect the Ambient Aerosol Condensation Nuclei Counter (CNC) Quantitative Fit Test (QNFT) Protocols in 29 CFR 1910.134, Appendix A.
With the Modified CNC protocols, the respirator fit testing process is faster and more streamlined. The modified CNC protocols enable fewer, shorter fit test exercises: Instead of eight exercises, the new rules require four. Total fit test time is reduced by almost 5 min.
You can comply faster without compromising safety!
VeriFit® Quantitative
Model MT-11
One of the most cost-effective and reliable QNFT units available today!
SIBATA SCIENTIFIC TECHNOLOGY LTD. is a world-wide leader in environmental testing and product development. They are well-known for the manufacture and sales of laboratory glassware as well as the manufacture and sales of environmental and occupational health measurement equipment that includes Respiratory Fit Testing instrumentation.
Sibata has 50 years of sales and product development in Respiratory Fit Testing!
1921 Sibata was founded.
:
1980 Manufacturing and sales of mask fitting test equipment for nuclear power plants.
:
2024 Starting with the MT-01 in 1980 and thru advancements in technology, Sibata has brought their latest model MT-11D to market.
Sibata and Nextteq have joined together in an exclusive arrangement to introduce VeriFit® Quantitative in the North American market, and also available in South American and European markets.
Model: VeriFit® MT-11D
Measurement Principle: Condensation Nucleus Counter (CNC)
*ratio measurement of particles inside and outside of a donned respirator
Measurement Target: Respirator fit around the face seal
Measurement Range: Counting range: 0.0 - 9,999,999 count
Leakage rate: 0.00 - 100.0%
Fit Factor/Protection Factor: 1.0~1,000,000
Measurement Item: Particle Count, Leakage Rate, Fit Factor, and Protection Factor
Particle Size: 99+mode: 0.02 - 1 μm, 95 mode: around 0.06 μm
Function: Leakage rate, protection factor, and fit factor calculation; RS-232C output, USB cable communications, and logging to USB memory stick
Suction Flow Rate: Total flow rate:1 L/min、Sample flow rate:0.25 L/min
Operating Environment: 59 - 86℉ /15 - 30℃, 30 - 90% RH(No condensation)
Power Supply: 100 - 240 V AC ±10%, 50/60 Hz, 1.0 A
Dimensions/Weight Approx. W8.27in x D10.83 in x H9.45in / W210 × D275 × H240 mm *mirror folded / Approx. 9.92lbs / 4.5 kg
Note Please prepare 99.5% or "reagent grade" isopropyl alcohol (IPA) separately.
SIBATA SCIENTIFIC TECHNOLOGY LTD
Ordering Information
VeriFit® Quantitative
Contact Nextteq today to be a part of our Pilot Program!
©2025 Nextteq International LLC. All rights reserved. Nextteq, Nextteq logo, NXI, NXI logo, VeriFit, VeriAir Flex, VeriAir, Multi-teq, and ReadyGo are a registered trademarks of Nextteq International LLC. All other brand names and trademarks mentioned in this document are the properties of their respective holders. All features, specifications, and prices are subject to change without notice.